Search
English
You have no items in your shopping cart.

Universal-Measuring Transducer/ Isolating Amplifier Type MU100U

Manufacturer:

Ziehl

Manufacturer part number:

T236010
Delivery date: 12 business days

Universal Measuring Transducer / Isolating Amplifier

224 CAD
PRICE BREAKS - Buy More, Save More
Quantity
10+
20+
Price
201.6 CAD
179.2 CAD
+ -
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24-240 V
Protection housing IP 40
Protection terminals IP 20
Tolerance DC DC 20,4 - 297 V
Voltage output DC 0/2 – 10 V
Current output DC 0/4 – 20 mA
Tolerance AC AC 19 - 264 V, Frequenz 20 - 120 Hz
Power consumption < 3 W
Fuse(A) 2
Input Voltage DC 0 - 10 V
Input current(mA) DC 0/ 4 - 20 mA
load resistance (current) Ω > 1000
Ambient temperature range 0…50°C

The universal measuring transducer MU100U can be connected to any supply voltage AC or DC between 24 and 240 V. Input signals and output signals are electrically isolated from each other. Signals DC 0/4-20 mA or 0-10 V can be connected to the inputs. The input signals are transduced to standard-signal 0-10 V, 0/4-20 mA at the outputs.

The measuring signal applied to one of the inputs is converted into a normalized voltage signal and changed into a frequency. The frequency signal is transferred by means of an optocoupler for electrical isolation. It is then converted again into a voltage and amplified. Signals 0/4-20 mA and 0-10 V are now available at the outputs. The electronics before and after the optocoupler are supplied from the power supply unit with potential separated voltages each.

It is often necessary to separate the potentials of signals by means of isolation amplifiers as otherwise this would lead to adulteration of measuring values because of compensating currents. Furthermore, the low-voltage side is effectively protected against damage caused by malfunctions at the primary side. Because of the variety of the current standard signals (0-20 mA, 4-20 mA, 0-10 V), it often happens that the output of a measuring transducer is not compatible with the input of the evaluation unit. MU 100 U eliminates these problems. Stockkeeping is largely facilitated by the universal supply voltage and different input and output signals in one device. These measuring transducers almost always fit.

  • Input signals DC 0 - 20 mA, 0 - 10 V
  • Output signals DC 0 - 20 mA, 0 - 10 V
  • Offset with signals 4 - 20 mA can be compensated by the user
  • Universal supply voltage AC/DC 24 - 240 V
  • electrical isolation between inputs and outputs
  • supply voltage for external measuring transducers -5/+18 V/ max. 30 mA
  • Isolation voltage 2.5 kV
Write your own review Close Review Form
  • Product can be reviewed only after purchasing it
  • Only registered users can write reviews
  • Bad
  • Excellent
General Catalog

Data Sheet

Video
Request For Quote
Description

The universal measuring transducer MU100U can be connected to any supply voltage AC or DC between 24 and 240 V. Input signals and output signals are electrically isolated from each other. Signals DC 0/4-20 mA or 0-10 V can be connected to the inputs. The input signals are transduced to standard-signal 0-10 V, 0/4-20 mA at the outputs.

The measuring signal applied to one of the inputs is converted into a normalized voltage signal and changed into a frequency. The frequency signal is transferred by means of an optocoupler for electrical isolation. It is then converted again into a voltage and amplified. Signals 0/4-20 mA and 0-10 V are now available at the outputs. The electronics before and after the optocoupler are supplied from the power supply unit with potential separated voltages each.

It is often necessary to separate the potentials of signals by means of isolation amplifiers as otherwise this would lead to adulteration of measuring values because of compensating currents. Furthermore, the low-voltage side is effectively protected against damage caused by malfunctions at the primary side. Because of the variety of the current standard signals (0-20 mA, 4-20 mA, 0-10 V), it often happens that the output of a measuring transducer is not compatible with the input of the evaluation unit. MU 100 U eliminates these problems. Stockkeeping is largely facilitated by the universal supply voltage and different input and output signals in one device. These measuring transducers almost always fit.

  • Input signals DC 0 - 20 mA, 0 - 10 V
  • Output signals DC 0 - 20 mA, 0 - 10 V
  • Offset with signals 4 - 20 mA can be compensated by the user
  • Universal supply voltage AC/DC 24 - 240 V
  • electrical isolation between inputs and outputs
  • supply voltage for external measuring transducers -5/+18 V/ max. 30 mA
  • Isolation voltage 2.5 kV
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24-240 V
Protection housing IP 40
Protection terminals IP 20
Tolerance DC DC 20,4 - 297 V
Voltage output DC 0/2 – 10 V
Current output DC 0/4 – 20 mA
Tolerance AC AC 19 - 264 V, Frequenz 20 - 120 Hz
Power consumption < 3 W
Fuse(A) 2
Input Voltage DC 0 - 10 V
Input current(mA) DC 0/ 4 - 20 mA
load resistance (current) Ω > 1000
Ambient temperature range 0…50°C
Product tags