Search
English
You have no items in your shopping cart.

Transmitter for temperature Type TMU100V

Manufacturer:

Ziehl

Manufacturer part number:

T236090
Delivery date: 12 business days

Measuring Transducer for Pt100, Housing Design V2 for circuit-breaker box.

175 CAD
PRICE BREAKS - Buy More, Save More
Quantity
10+
20+
Price
158.2 CAD
140 CAD
+ -
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24 – 240 V 0/50/60 Hz < 3 W < 5 VA
Tolerance DC DC 20,4 - 297 V
Tolerance AC AC 20 - 264 V
Sensor Pt 100 according to EN 60751 (2/3-wire version)
Sensor current ≤ 0,8 mA
Rated impulse voltage(V) 4000
Rated insulation voltage Ui(V) 250
Protection housing IP 30
Protection terminals IP 20
Applied standards UL/CSA

Model TMU100 Pt100 measuring transducers are suitable for measuring temperatures with sensors Pt100 (RTD). Zero and Full-scale can be freely set within the whole range -199 ...+850 °C. To do this, only resistors with the according value or a Pt 100-decade is connected. The adjustment is done by pressing a button.

The built-in universal power supply AC/DC 24-240 V allows the connection to all common supply-voltages. The Pt100- sensor can be connected in 2- or 3-wire connection. The output delivers 0/4 ... 20 mA and 0 ... 10 V simultaneously.

Overview of functions

  • Pt100-input 2- or 3-wire automatic compensation of line up to 500 Ω total resistance (sensor + line)
  • Detection of sensor-break
  • Easy adjustment of Zero and Full-scale by pressing a button
  • Wide measuring-range -200... +850 °C
  • LEDs for display of operative state
  • Analog output 0 ... 20 mA / 4 ... 20 mA. Analog output 0 ... 10 V
  • Housing for DIN-rail or wall-mount, 35 mm wide, mounting height 55 mm
  • Universal supply AC/DC 24-240 V
Write your own review Close Review Form
  • Product can be reviewed only after purchasing it
  • Only registered users can write reviews
  • Bad
  • Excellent
General Catalog

Data Sheet

Video
Request For Quote
Description

Model TMU100 Pt100 measuring transducers are suitable for measuring temperatures with sensors Pt100 (RTD). Zero and Full-scale can be freely set within the whole range -199 ...+850 °C. To do this, only resistors with the according value or a Pt 100-decade is connected. The adjustment is done by pressing a button.

The built-in universal power supply AC/DC 24-240 V allows the connection to all common supply-voltages. The Pt100- sensor can be connected in 2- or 3-wire connection. The output delivers 0/4 ... 20 mA and 0 ... 10 V simultaneously.

Overview of functions

  • Pt100-input 2- or 3-wire automatic compensation of line up to 500 Ω total resistance (sensor + line)
  • Detection of sensor-break
  • Easy adjustment of Zero and Full-scale by pressing a button
  • Wide measuring-range -200... +850 °C
  • LEDs for display of operative state
  • Analog output 0 ... 20 mA / 4 ... 20 mA. Analog output 0 ... 10 V
  • Housing for DIN-rail or wall-mount, 35 mm wide, mounting height 55 mm
  • Universal supply AC/DC 24-240 V
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24 – 240 V 0/50/60 Hz < 3 W < 5 VA
Tolerance DC DC 20,4 - 297 V
Tolerance AC AC 20 - 264 V
Sensor Pt 100 according to EN 60751 (2/3-wire version)
Sensor current ≤ 0,8 mA
Rated impulse voltage(V) 4000
Rated insulation voltage Ui(V) 250
Protection housing IP 30
Protection terminals IP 20
Applied standards UL/CSA
Product tags