Search
English
You have no items in your shopping cart.

Relay for Energy Flow Model: EFR4001IP

Manufacturer:

Ziehl

Manufacturer part number:

S225762
Delivery date: 12 business days

Relay for Energy Flow, optimization of consumption of self-consumption of self generated energy. Zero Export Device.

1057 CAD
PRICE BREAKS - Buy More, Save More
Quantity
10+
20+
Price
950.6 CAD
845.6 CAD
+ -
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage DC/AC 24 – 270 V 0/40...70 Hz, <3 W, <9 VA
Tolerance DC DC 20,4 - 297 V
Tolerance AC AC 20 - 264 V
Switching voltage max. AC 300 V, DC 300 V
Conventionel thermal current Ith max. 9 A
Switching power max cos φ=1 2000 VA
Contact service life, electr. cos φ=1 10^5 operations at 300 V / 9 A
Rated operational current AC-15 Ie = 6 A Ue = 250 V
Measurement of voltage (RMS) L1 / L2 / L3 towardsN
Voltage phase-N AC 40,0 … 330,0 V, 50/60 Hz
Nominal currents / resolution AC 1/5 A / 1 mA
Overload capacity 8 A continously, 25 A max. 1 s
Operating temperature (°C) -20 ~55
Protection housing/terminals IP 30 / IP20

Relays for energy flow EFR4001IP monitor the current flow between public power grid and generating plant / consumer. Operation is made comfortably via integrated webserver or directly at the device. Measured values are displayed neatly arranged at device on monitor. When the own power plant generates more power than actually is consumed it often is more economical to consume the excess energy self. This is especially reasonable when the difference is high between the price you pay to the grid provider and the price the provider pays for fed in energy.

Many areas suitable for photovoltaics could not be used so far, since only a limited amount of power can be fed in at the grid connection point. In Germany new standards allow exceeding this value by up to 2/3 (66.6%) installed capacity. The prerequisite for this is that the overbuilt power is consumed and not fed into the grid. In order to still ensure the stability of the system, this must be monitored. The same applies to zero export, when no energy at all may be fed into the grid. In this case, the device can be used as an energy flow direction sensor (EnFluRi). The EFR4001IP has been optimized for these functions.

 

Zero-Export-Device or limiter:

  • Switching off the power generation system or parts of it if the permissible feed-in power is exceeded with relay K3
  • Switching on consumers or reducing generators before it comes to that by means of regulating with an analogue output or switching loads with relays K1 and K2
  • Energy flow direction sensor (EnFluRi sensor) and feed-in limitation < 0.1s

 

Functions

  • Switching of up to 3 consumers: the largest consumer, ranked 1-2-3 or combination of 3 consumers (7 levels)
  • Switch on and off points. At which energy flow consumers are switched on and off again
  • Switch on and off delay of consumers, minimum on time.
  • Control of heat pumps (SG-ready), battery chargers, inverters
  • Switching on consumers or reducing generators before it comes to that by means of regulating with an analogue output or switching loads with relays K1 and K2
  • Energy flow direction sensor (EnFluRi sensor) and feed-in limitation < 0.1s

 

Features

  • Measuring of active power 1- or 3-phase up to 1.000 kW (more with factor)
  • Counters for power (feed in and consumption)
  • Operation at device with color display (LCD) and joystick
  • 3 inputs for customary current transformers with secondary 1 or 5 A.
  • 3 relay outputs
  • 4 digital inputs Y1-Y4 for control signals, e.g. relay on or off
  • IP-connection, integrated webserver
  • Interface ethernet TCP/IP, values available via modbus TCP
  • Analog outputs as measuring transducer and for stepless regulation of a consumer
  • Switch gear housing 140 mm wide

 

Suitable current transformers:

  • Usual current transformers up to 1,000 A, secondary 1 A or 5 A (for Pav,e min. class 1), e.g. ZIEHL type AS or WS
  • Compact CTM7 CTM7, 64/1 A, Kl. 1, 0,5 VA
  • Split core KBR18S KBR18S, 60/1 A, Kl. 3, 0,4 VA (not for Pav,e)
Write your own review Close Review Form
  • Product can be reviewed only after purchasing it
  • Only registered users can write reviews
  • Bad
  • Excellent
General Catalog

Data Sheet

Video
Request For Quote
Description

Relays for energy flow EFR4001IP monitor the current flow between public power grid and generating plant / consumer. Operation is made comfortably via integrated webserver or directly at the device. Measured values are displayed neatly arranged at device on monitor. When the own power plant generates more power than actually is consumed it often is more economical to consume the excess energy self. This is especially reasonable when the difference is high between the price you pay to the grid provider and the price the provider pays for fed in energy.

Many areas suitable for photovoltaics could not be used so far, since only a limited amount of power can be fed in at the grid connection point. In Germany new standards allow exceeding this value by up to 2/3 (66.6%) installed capacity. The prerequisite for this is that the overbuilt power is consumed and not fed into the grid. In order to still ensure the stability of the system, this must be monitored. The same applies to zero export, when no energy at all may be fed into the grid. In this case, the device can be used as an energy flow direction sensor (EnFluRi). The EFR4001IP has been optimized for these functions.

 

Zero-Export-Device or limiter:

  • Switching off the power generation system or parts of it if the permissible feed-in power is exceeded with relay K3
  • Switching on consumers or reducing generators before it comes to that by means of regulating with an analogue output or switching loads with relays K1 and K2
  • Energy flow direction sensor (EnFluRi sensor) and feed-in limitation < 0.1s

 

Functions

  • Switching of up to 3 consumers: the largest consumer, ranked 1-2-3 or combination of 3 consumers (7 levels)
  • Switch on and off points. At which energy flow consumers are switched on and off again
  • Switch on and off delay of consumers, minimum on time.
  • Control of heat pumps (SG-ready), battery chargers, inverters
  • Switching on consumers or reducing generators before it comes to that by means of regulating with an analogue output or switching loads with relays K1 and K2
  • Energy flow direction sensor (EnFluRi sensor) and feed-in limitation < 0.1s

 

Features

  • Measuring of active power 1- or 3-phase up to 1.000 kW (more with factor)
  • Counters for power (feed in and consumption)
  • Operation at device with color display (LCD) and joystick
  • 3 inputs for customary current transformers with secondary 1 or 5 A.
  • 3 relay outputs
  • 4 digital inputs Y1-Y4 for control signals, e.g. relay on or off
  • IP-connection, integrated webserver
  • Interface ethernet TCP/IP, values available via modbus TCP
  • Analog outputs as measuring transducer and for stepless regulation of a consumer
  • Switch gear housing 140 mm wide

 

Suitable current transformers:

  • Usual current transformers up to 1,000 A, secondary 1 A or 5 A (for Pav,e min. class 1), e.g. ZIEHL type AS or WS
  • Compact CTM7 CTM7, 64/1 A, Kl. 1, 0,5 VA
  • Split core KBR18S KBR18S, 60/1 A, Kl. 3, 0,4 VA (not for Pav,e)
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage DC/AC 24 – 270 V 0/40...70 Hz, <3 W, <9 VA
Tolerance DC DC 20,4 - 297 V
Tolerance AC AC 20 - 264 V
Switching voltage max. AC 300 V, DC 300 V
Conventionel thermal current Ith max. 9 A
Switching power max cos φ=1 2000 VA
Contact service life, electr. cos φ=1 10^5 operations at 300 V / 9 A
Rated operational current AC-15 Ie = 6 A Ue = 250 V
Measurement of voltage (RMS) L1 / L2 / L3 towardsN
Voltage phase-N AC 40,0 … 330,0 V, 50/60 Hz
Nominal currents / resolution AC 1/5 A / 1 mA
Overload capacity 8 A continously, 25 A max. 1 s
Operating temperature (°C) -20 ~55
Protection housing/terminals IP 30 / IP20
Product tags