Level Monitor for conductive liquids, 1 Niveau, 1 oder 2 Limits, MIN / MAX-control, adjustable sensitivity, Housing Design V2 for circuit-breaker-box

135.8 CAD
PRICE BREAKS - Buy More, Save More
Quantity
10+
20+
Price
123.2 CAD
109.2 CAD
+ -
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24 – 240 V 0/50/60 Hz < 3 W < 5 VA
Tolerance DC DC 20,4 - 297 V
Tolerance AC AC 20 - 264 V
Switching voltage max(V) 415
Switching current max(A) 6
Switching power max(W) 120
Rated impulse voltage(V) 4000
Rated insulation voltage Ui(V) 250
Ambient temperature range -20...+60 °C
Protection housing/terminals IP 30 / IP20
Applied standards UL/CSA

Level-Relays NS 20 for conductive liquids can be used as monitors for 1 Level and for controlling a level between 2 electrodes.

  • 3 elektrodes for MIN/MAXcontrol
  • 2 elektrodes (E2 open) as level monitor
  • Sensitivity adjustable 5 kΩ…250 kΩ
  • LED for state of relay
  • Function of relay reversible (picks up or releases at top electrode)
  • Switching-delay adjustable 0,1…10 s
  • Housing 35 mm wide, mounting height 55 mm
  • Universal supply-voltage AC/DC 24-240 V

Application level monitor

Protection from running dry or overflow, monitoring of pumps for leaks, detection of leaks.

Application Min/Max

Controlling a level between minimum (elektrode E2) and maximum (E3). As long as E3 is dry, a magnetic valve is opened (or a pump is running) and liquid is influenting. As soon as maximum (E3) is reached, the NS 20 closes the valve. When the level falls below E2, the cycle starts new. In reverse also discharging of a container can be controlled.

Overview of functions example filling with 2 electrodes

The detection of the level is made with a DC-free measuring of resistance between all electrodes The common electrode in E 1. A magnetic valve that is switched with relay-contacts 15-18 opens and lets liquid in until the upper electrode E3 is in contact with the liquid. Then the relay releases (15-18 open) and the valve closes. The relay remains released as long as electrode E 2 is in contact with the liquid. When the level falls below E2, the relay picks up (LED Relay on, 15-18 close) and the procedure starts new with opening the valve. Thus thelevel of the liquid is kept between E 1 and E 2.

For monitoring one level only or in applications to protect from running dry or overflow or leak detection, only electrodes E1 and E3 are connected.

Write your own review Close Review Form
  • Product can be reviewed only after purchasing it
  • Only registered users can write reviews
  • Bad
  • Excellent
General Catalog

Data Sheet

Video
Request For Quote
Description

Level-Relays NS 20 for conductive liquids can be used as monitors for 1 Level and for controlling a level between 2 electrodes.

  • 3 elektrodes for MIN/MAXcontrol
  • 2 elektrodes (E2 open) as level monitor
  • Sensitivity adjustable 5 kΩ…250 kΩ
  • LED for state of relay
  • Function of relay reversible (picks up or releases at top electrode)
  • Switching-delay adjustable 0,1…10 s
  • Housing 35 mm wide, mounting height 55 mm
  • Universal supply-voltage AC/DC 24-240 V

Application level monitor

Protection from running dry or overflow, monitoring of pumps for leaks, detection of leaks.

Application Min/Max

Controlling a level between minimum (elektrode E2) and maximum (E3). As long as E3 is dry, a magnetic valve is opened (or a pump is running) and liquid is influenting. As soon as maximum (E3) is reached, the NS 20 closes the valve. When the level falls below E2, the cycle starts new. In reverse also discharging of a container can be controlled.

Overview of functions example filling with 2 electrodes

The detection of the level is made with a DC-free measuring of resistance between all electrodes The common electrode in E 1. A magnetic valve that is switched with relay-contacts 15-18 opens and lets liquid in until the upper electrode E3 is in contact with the liquid. Then the relay releases (15-18 open) and the valve closes. The relay remains released as long as electrode E 2 is in contact with the liquid. When the level falls below E2, the relay picks up (LED Relay on, 15-18 close) and the procedure starts new with opening the valve. Thus thelevel of the liquid is kept between E 1 and E 2.

For monitoring one level only or in applications to protect from running dry or overflow or leak detection, only electrodes E1 and E3 are connected.

Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24 – 240 V 0/50/60 Hz < 3 W < 5 VA
Tolerance DC DC 20,4 - 297 V
Tolerance AC AC 20 - 264 V
Switching voltage max(V) 415
Switching current max(A) 6
Switching power max(W) 120
Rated impulse voltage(V) 4000
Rated insulation voltage Ui(V) 250
Ambient temperature range -20...+60 °C
Protection housing/terminals IP 30 / IP20
Applied standards UL/CSA