3 Items in Grid
4 Items in Grid
List
Filter by attributes
-
Primary nominal current(A)
-
60
-
Secondary nominal current(A)
-
1
-
Pick-up delay after recovery of Us
-
< 0,5 s
-
Rated supply voltage
-
AC 230 V
-
AC 400V
-
AC/DC 24 V
-
AC690 V
-
3 AC 400 V, 50/60 Hz < 3 VA
-
3-phase 380-415 V, without neutral
-
3-phase, 400 V without N
-
AC 220 - 240 V, ± 10%, 50/ 60 Hz, < 3 VA
-
AC 230 V, +10%/-15%, 3VA, 50 Hz
-
AC 230 V, +10...-30%, < 5 VA
-
AC/ DC 24V - 240V, < 1,5W, < 5 VA
-
AC/DC 24 – 240 V 0/50/60 Hz < 3 W < 5 VA
-
AC/DC 24 – 240 V 0/50…400 Hz < 3 W < 8 VA
-
AC/DC 24 - 240 V, < 3 W, < 5 VA, (AC 20 - 264 V, DC 20,4 - 297 V)
-
AC/DC 24 - 240 V, 0/50/60 Hz, < 2 W, < 3 VA
-
AC/DC 24 - 240 V, 0/50/60 Hz, < 4 W, < 8 VA DC: 20,4 ... 297 V, AC: 20 ... 264 V < 2 W, < 6 VA
-
AC/DC 24 - 240 V, AC 20 - 264 V, DC 20 - 297 V, < 1 W , < 4 VA
-
AC/DC 24-240 V
-
AC/DC 24-240 V, <3W, <10VA (AC 20-264 V, DC 20,4-297 V)
-
AC/DC 24-270 V, 0/40...70 Hz, <1,8W / <6,5 VA
-
AC/DC 24-270 V, 0/40...70 Hz, <5VA
-
AC/DC 24-270 V, 0/45...65 Hz, <5VA
-
AC/DC 24-270 V, 0/50/60 Hz, <4.5 W, < 12 VA
-
AC230 V
-
DC 10 ... 30 V, max. 22 mA, typ . <13 mA
-
DC 20 - 30 V, < 2 VA
-
DC 24 V, 10,0 ... 30,0 V, <0,25 W
-
DC 24 V, SELV, PELV
-
DC 24V
-
DC 9...30 V (2-wire), alterable with bridge
-
DC/AC 24 – 270 V 0/40...70 Hz, <3 W, <9 VA
-
Primary nominal current (A)
-
64
-
Secondary nominal current
-
1
-
load resistance (current) Ω
-
≤ 500
-
Protection terminals
-
IP 20
-
Rated continuous residual current(A)
-
40
-
Switching current max(A)
-
0.5
-
5
-
6
-
Switching power max(W)
-
120
-
48
Current Relay for AC-Detection, AND-Evaluation, 3 Transformers, Housing type K for switch-gear cabinet mount
Current Relay for AC-Detection, AND-Evaluation, 3 Transformers
Current sensor for AC- and DC currents, Put-on sensor with transistor output
Current transformer for DIN-rail mount or screw mount, for regognition of AC currents
Limit Relay for DC standard signals 0/4 - 20 mA, 0/2 - 10 V
AC Electronic current transducer with analog output, Measuring transducer for AC currents
AC Electronic current transformer with freqency output
AC Electronic current transformer with analog output, 2 measuring ranges, 2-wire execution
AC Electronic current transformer, AC 0 - 60 A, with interface RS485
AC Electronic current transormer, adjustable limit AC 2-10 A, transistor-output, LED
AC Electronic current transformer, fixed switching point
Frequency- and Speed Relay
with integrated Measuring Transducer
Frequency- and Speed Relay
with integrated Measuring Transducer
For housings for cabinet mount V4, V6, V8. Installation frame for mounting in control panels or doors.
For housings for cabinet mount V4, V6, V8. Installation frame for mounting in control panels or doors.
For housings for cabinet mount V4, V6, V8. Installation frame for mounting in control panels or doors.
Universal Measuring Transducer for DC voltage and DC current, isolation amplifier, scaleable
Monitor for 3-phase, Phase Asymmetry, Phase Sequence, Over- and Under voltage
Monitor for 3-phase, Phase Asymmetry, Phase Sequence, Over- and Under voltage
Load- and Current monitor, active current with direction, over- and underload, cosfi