Rechercher
Français

Measuring Point Change-over Switch Type MUM16

Fabricant:

Ziehl

Numéro de pièce du fabricant:

T236035
Délai de livraison: 2 Weeks

Measuring point change-over switch, for 16 Measuring points

502 CAD
+ -
Spécifications des produits
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24-240 V
Frequency Range(Hz) 0/ 50/ 60 Hz
Protection housing IP 20
Protection terminals IP 20
Power consumption < 6,5 VA, 4 W
Tolerance AC AC -10…+10%
Ambient temperature range -20...+55 °C
Switching voltage max. AC/ DC 24 V
Switching current max. 100 mA
Switching capacity max. 2,4 W or 2,4 VA (ohmic Load)

Measuring point change-over switches allow the connection of up to 16 measuring points to 1 measuring device, e.g. an analog input of a PLC.

The inputs can be selected with a BCD-Code. Manual selection can be made with a code-switch. 

In automatic mode, the inputs are polled (tact-time adjustabe) and thus be displayed in succession. When using a measuring point change-over switch, only 1 measuring input is needed to collect multiple values.
Especially with slowly changing signals like temperatures, measuring every other second is enough. Expensive inputs for Pt100 or 0-10 V/0-20 mA at PLCs can be saved.

With the MUM16, alternatively 16 measuring points with common ground or 8 measuring points with separated ground can be switched.

Entrez votre propre avis fermer
  • Un produit ne peut être commenté qu'après avoir été acheté
  • Seuls les utilisateurs enregistrés peuvent saisir des avis
  • Mauvais
  • Excellent
Description

Measuring point change-over switches allow the connection of up to 16 measuring points to 1 measuring device, e.g. an analog input of a PLC.

The inputs can be selected with a BCD-Code. Manual selection can be made with a code-switch. 

In automatic mode, the inputs are polled (tact-time adjustabe) and thus be displayed in succession. When using a measuring point change-over switch, only 1 measuring input is needed to collect multiple values.
Especially with slowly changing signals like temperatures, measuring every other second is enough. Expensive inputs for Pt100 or 0-10 V/0-20 mA at PLCs can be saved.

With the MUM16, alternatively 16 measuring points with common ground or 8 measuring points with separated ground can be switched.

Spécifications des produits
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24-240 V
Frequency Range(Hz) 0/ 50/ 60 Hz
Protection housing IP 20
Protection terminals IP 20
Power consumption < 6,5 VA, 4 W
Tolerance AC AC -10…+10%
Ambient temperature range -20...+55 °C
Switching voltage max. AC/ DC 24 V
Switching current max. 100 mA
Switching capacity max. 2,4 W or 2,4 VA (ohmic Load)
Tags des produits