Rechercher
Français

Universal Measuring Transducer Type MU2000K

Fabricant:

Ziehl

Numéro de pièce du fabricant:

T236053
Délai de livraison: 10 business days

Measuring Transducer AC and DC, for Voltage and Current, scaleable

279 CAD
Réductions de prix - Plus vous achetez, plus vous économisez
Quantité
10+
20+
Prix
252 CAD
223,5 CAD
+ -
Spécifications des produits
Brand ZIEHL
Country of origin Germany
Input Voltage AC/DC 0-30/150/300/600 V, 80-120 V, Ri = 500 kΩ, max. 600 V, max. 300 V to GND
Rated supply voltage AC/DC 24 – 240 V 0/50…400 Hz < 3 W < 8 VA
Protection housing IP 40
Protection terminals IP 20
Ambient temperature range -20 °C ... +50 °C
Error 0,3 % of current x (250Ω - load) / 250Ω
Input current(mA) AC/DC 1A, 5A, max. 7,5A/4s, 25A/1s, 30 mΩ
Output Voltage DC 0/2-10 V, load min. 1 kΩ
Output current(A) DC 0/4-20 mA, load max. 500 Ω

Measuring transducers MU2000K can measure DC- an AC-voltages up to 600 V and DC- and AC-currents 0-1/5 A.

Preset measuring ranges can be selected. More measuring ranges (zero and full-scale) can be easily scaled. The output signals DC 0/2-10 V and 0/4-20 mA are insulated from measuring input and supply voltage. With its universal supply voltage AC/DC 24-240 V the measuring transducer can be connected to all common supply voltages.

The MU2000K e.g. is suitable for measuring DC voltages and charging currents at batteries or for measuring AC voltages and currents in plants for own generation of energy.

Entrez votre propre avis fermer
  • Un produit ne peut être commenté qu'après avoir été acheté
  • Seuls les utilisateurs enregistrés peuvent saisir des avis
  • Mauvais
  • Excellent
General Catalog

Data Sheet

Video
Request For Quote
Description

Measuring transducers MU2000K can measure DC- an AC-voltages up to 600 V and DC- and AC-currents 0-1/5 A.

Preset measuring ranges can be selected. More measuring ranges (zero and full-scale) can be easily scaled. The output signals DC 0/2-10 V and 0/4-20 mA are insulated from measuring input and supply voltage. With its universal supply voltage AC/DC 24-240 V the measuring transducer can be connected to all common supply voltages.

The MU2000K e.g. is suitable for measuring DC voltages and charging currents at batteries or for measuring AC voltages and currents in plants for own generation of energy.

Spécifications des produits
Brand ZIEHL
Country of origin Germany
Input Voltage AC/DC 0-30/150/300/600 V, 80-120 V, Ri = 500 kΩ, max. 600 V, max. 300 V to GND
Rated supply voltage AC/DC 24 – 240 V 0/50…400 Hz < 3 W < 8 VA
Protection housing IP 40
Protection terminals IP 20
Ambient temperature range -20 °C ... +50 °C
Error 0,3 % of current x (250Ω - load) / 250Ω
Input current(mA) AC/DC 1A, 5A, max. 7,5A/4s, 25A/1s, 30 mΩ
Output Voltage DC 0/2-10 V, load min. 1 kΩ
Output current(A) DC 0/4-20 mA, load max. 500 Ω
Tags des produits