Delivery date: 2 business days

Web-IO Universal-Relay, 8 Sensors/Inputs, DC Signals, Pt100, Thermoelements, 4 Limits, Web IO with Interface RS485, operation with browser via TCP/IP

1498 CAD
PRICE BREAKS - Buy More, Save More
Quantity
10+
20+
Price
1348.2 CAD
1198.4 CAD
+ -
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24-240 V
Tolerance DC DC 20,4 - 297 V
Tolerance AC AC 20 - 264 V
Power consumption < 4 W, < 13 VA
Switching voltage max. AC 415 V
Switching current max. 5 A
Switching power max. 1250 VA (resistive load), max. 120 W at DC 24 V
Protection housing IP 30
Protection terminals IP 20
Nominal operational current Ie AC15 Ie = 3 A Ue = 250 V
Nominal operational current Ie DC13 Ie = 2 A ..... Ue = 24 V Ie = 0,2A ..... Ue = 125 V Ie = 0,1A ..... Ue = 250 V
Rated impulse voltage(V) 4000
Ambient temperature range -20 °C ... +65 °C
Storage temperature(°C) -20 ~ 70
Cable Length max. 1000 m at 19200 baud
Applied standards UL/CSA

The TR800Web can be connected to the internet or an intranet and operated via TCP/IP from a normal PC with a suitable browser. No special software and no special instruction is necessary. The Universal-Relay TR800Web monitors and logs signals from up to 8 inputs. Up to 8 limits (one per input) can be programmed for each of the 4 output-relays. Thus e.g. alarm 1 can be activated when the temperature at a sensor (e.g. Pt100) at input 1 exceeds a limit or when the signal of a transmitter for pressure (e.g. 4-20 mA) at input 5 falls below a limit. It can also send an email when a limit is exceeded and/or when the signals falls short of the limit again. A day/night switchover allows to vary limits depending on daytime. In addition the device has an interface RS485 with the protocols Modbus and ZIEHL-standard.

>Accessory: Installation frame ER8 for panel mount

Applications

The TR800Web is used where one or more of the following features a required:

  • measuring of up to 8 analog signals and transmit the data via TCP/IP
  • reading of measured values and teleservice via internet/intranet
  • signalling of alarms via email when limits are exceeded
  • monitoring of filling level (water, gasoil) with ZIEHL filling level probe NS6123-6
  • logging of measured values and remote inquiry e.g. for monitoring temperatures at engines and in plants

8 Measuring inputs (every input individually programmable)

  • Pt 100, Pt 1000 in 2- or 3-wire connection
  • KTY 83 or KTY 84
  • Thermocouples type B, E, J, K, L, N, R, S, T
  • DC 0-10 V, DC 0/4-20 mA
  • Resistance 500 Ohm, resistance 30 kOhm
  • Difference of 2 signals

4 Alarms

  • 4 relays, potential-free change-over contacts
  • Remote switching of relays via Ethernet
  • or every alarm separately programmable
    • one limit per input (limit and switching-back-value)
    • second set of values switchable day/night
    • switching-delay and switching-back delay
    • remote operation of relays (on/off) with browser
    • interlocked switching
    • email at alarm

Programmable via internet in web-browser

  • display of measured values, min- and max-values with date/time-stamp
  • simulation of measured values
  • state of alarms
  • configuration of inputs (name, compensation, scaling and measuring-unit)
  • configuration of alarms (limits, function of relays, ...)
  • time-depending day/night changing of limits
  • logging of up to 150.000 values per input, alarms with date/time-stamp
  • logging-interval adjustable 2 seconds to 24 hours
  • Alarmlogging
  • configuration of network
  • settings of system
  • administration of users and code-protection
  • real-time clock with synchronizing with time-server, reserve 7 days

Interfaces:

  • Ethernet interface (http, https, UDP and Modbus)
    • http (port can be selected and switched off) and https
    • tp-upload for automatic (interval adjustable)
    • storage of logged data on ftp-server
    • UDP- and Modbus protocol to read data (port can be selected)
    • AJAX for data-readout in html
    • SNMP
  • RS485 interface to readout data with modbus (RTU) and ZIEHL-protocol

Displays and Operating elements

  • 8 LEDs for inputs
  • 4 LEDs for alarms, 4 LEDs for state of relays
  • 4 digit display for measuring values
  • 3 buttons for reading measured values at the device and for setting of IP-adress
  • switch IP 10.10.10.10 / user
  • reset-button
  • LEDs for activity of interfaces
Write your own review Close Review Form
  • Product can be reviewed only after purchasing it
  • Only registered users can write reviews
  • Bad
  • Excellent
General Catalog

Data Sheet

Video
Request For Quote
Description

The TR800Web can be connected to the internet or an intranet and operated via TCP/IP from a normal PC with a suitable browser. No special software and no special instruction is necessary. The Universal-Relay TR800Web monitors and logs signals from up to 8 inputs. Up to 8 limits (one per input) can be programmed for each of the 4 output-relays. Thus e.g. alarm 1 can be activated when the temperature at a sensor (e.g. Pt100) at input 1 exceeds a limit or when the signal of a transmitter for pressure (e.g. 4-20 mA) at input 5 falls below a limit. It can also send an email when a limit is exceeded and/or when the signals falls short of the limit again. A day/night switchover allows to vary limits depending on daytime. In addition the device has an interface RS485 with the protocols Modbus and ZIEHL-standard.

>Accessory: Installation frame ER8 for panel mount

Applications

The TR800Web is used where one or more of the following features a required:

  • measuring of up to 8 analog signals and transmit the data via TCP/IP
  • reading of measured values and teleservice via internet/intranet
  • signalling of alarms via email when limits are exceeded
  • monitoring of filling level (water, gasoil) with ZIEHL filling level probe NS6123-6
  • logging of measured values and remote inquiry e.g. for monitoring temperatures at engines and in plants

8 Measuring inputs (every input individually programmable)

  • Pt 100, Pt 1000 in 2- or 3-wire connection
  • KTY 83 or KTY 84
  • Thermocouples type B, E, J, K, L, N, R, S, T
  • DC 0-10 V, DC 0/4-20 mA
  • Resistance 500 Ohm, resistance 30 kOhm
  • Difference of 2 signals

4 Alarms

  • 4 relays, potential-free change-over contacts
  • Remote switching of relays via Ethernet
  • or every alarm separately programmable
    • one limit per input (limit and switching-back-value)
    • second set of values switchable day/night
    • switching-delay and switching-back delay
    • remote operation of relays (on/off) with browser
    • interlocked switching
    • email at alarm

Programmable via internet in web-browser

  • display of measured values, min- and max-values with date/time-stamp
  • simulation of measured values
  • state of alarms
  • configuration of inputs (name, compensation, scaling and measuring-unit)
  • configuration of alarms (limits, function of relays, ...)
  • time-depending day/night changing of limits
  • logging of up to 150.000 values per input, alarms with date/time-stamp
  • logging-interval adjustable 2 seconds to 24 hours
  • Alarmlogging
  • configuration of network
  • settings of system
  • administration of users and code-protection
  • real-time clock with synchronizing with time-server, reserve 7 days

Interfaces:

  • Ethernet interface (http, https, UDP and Modbus)
    • http (port can be selected and switched off) and https
    • tp-upload for automatic (interval adjustable)
    • storage of logged data on ftp-server
    • UDP- and Modbus protocol to read data (port can be selected)
    • AJAX for data-readout in html
    • SNMP
  • RS485 interface to readout data with modbus (RTU) and ZIEHL-protocol

Displays and Operating elements

  • 8 LEDs for inputs
  • 4 LEDs for alarms, 4 LEDs for state of relays
  • 4 digit display for measuring values
  • 3 buttons for reading measured values at the device and for setting of IP-adress
  • switch IP 10.10.10.10 / user
  • reset-button
  • LEDs for activity of interfaces
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24-240 V
Tolerance DC DC 20,4 - 297 V
Tolerance AC AC 20 - 264 V
Power consumption < 4 W, < 13 VA
Switching voltage max. AC 415 V
Switching current max. 5 A
Switching power max. 1250 VA (resistive load), max. 120 W at DC 24 V
Protection housing IP 30
Protection terminals IP 20
Nominal operational current Ie AC15 Ie = 3 A Ue = 250 V
Nominal operational current Ie DC13 Ie = 2 A ..... Ue = 24 V Ie = 0,2A ..... Ue = 125 V Ie = 0,1A ..... Ue = 250 V
Rated impulse voltage(V) 4000
Ambient temperature range -20 °C ... +65 °C
Storage temperature(°C) -20 ~ 70
Cable Length max. 1000 m at 19200 baud
Applied standards UL/CSA