Rechercher
Français

Current-Relay STW20V

Fabricant:

Ziehl

Numéro de pièce du fabricant:

S225124
Délai de livraison: 2 Weeks

Current Relay for AC-Detection, AND-Evaluation, 3 Transformers

119 CAD
+ -
Spécifications des produits
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24 - 240 V, < 3 W, < 5 VA, (AC 20 - 264 V, DC 20,4 - 297 V)
Overload capacity 100 A / 300 A
Ambient temperature range -20...+55 °C
Protection housing IP 30
Protection terminals IP 20
Applied standards UL/CSA

The current relay STW20V monitors the current in up to 3 lines with current transformers STWA 1 (AND circuit). If there is a current in all 3 monitored lines, the relay (2 change-over contacts) picks up. If there is no current in at least one of the lines, the relay releases.

The relay works in closed circuit current. When voltage is applied to the STW, the relay signals an alarm until the it has picked up. This can be avoided if the device is constantly alive and monitoring is started by closing a contact at the Enable input. With a bridge at the Enable input, monitoring is automatically started when voltage is applied.

  • 3 inputs (transformer STWA1)
  • 3 x current-sensor S1 (powersupply required)
  • AND-evaluation
  • output relay 2 CO
  • switching point app. AC 1 A
  • Enable-input
  • storage of alarms or Auto-Reset
  • LEDs power on and alarm 
  • housing V4 for mounting on DIN-rail or wall-mount

Applications

Identifies power failure with 1- or 3-phase electrical consumers, e.g. with monitoring of heating elements or heating installations where a constant heating has to be guaranteed.

A further application is the identification of phase failure, monitoring of fuses, or triggering of operating hours counters.

Entrez votre propre avis fermer
  • Un produit ne peut être commenté qu'après avoir été acheté
  • Seuls les utilisateurs enregistrés peuvent saisir des avis
  • Mauvais
  • Excellent
Description

The current relay STW20V monitors the current in up to 3 lines with current transformers STWA 1 (AND circuit). If there is a current in all 3 monitored lines, the relay (2 change-over contacts) picks up. If there is no current in at least one of the lines, the relay releases.

The relay works in closed circuit current. When voltage is applied to the STW, the relay signals an alarm until the it has picked up. This can be avoided if the device is constantly alive and monitoring is started by closing a contact at the Enable input. With a bridge at the Enable input, monitoring is automatically started when voltage is applied.

  • 3 inputs (transformer STWA1)
  • 3 x current-sensor S1 (powersupply required)
  • AND-evaluation
  • output relay 2 CO
  • switching point app. AC 1 A
  • Enable-input
  • storage of alarms or Auto-Reset
  • LEDs power on and alarm 
  • housing V4 for mounting on DIN-rail or wall-mount

Applications

Identifies power failure with 1- or 3-phase electrical consumers, e.g. with monitoring of heating elements or heating installations where a constant heating has to be guaranteed.

A further application is the identification of phase failure, monitoring of fuses, or triggering of operating hours counters.

Spécifications des produits
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24 - 240 V, < 3 W, < 5 VA, (AC 20 - 264 V, DC 20,4 - 297 V)
Overload capacity 100 A / 300 A
Ambient temperature range -20...+55 °C
Protection housing IP 30
Protection terminals IP 20
Applied standards UL/CSA
Tags des produits