Search
English
You have no items in your shopping cart.

Control for suction plants Type STW84V

Manufacturer:

Ziehl

Manufacturer part number:

S225522
Delivery date: 12 business days

Monitoring of 8 machines (STWA1(H) or contact)

644 CAD
PRICE BREAKS - Buy More, Save More
Quantity
10+
20+
Price
579.6 CAD
515.2 CAD
+ -
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24-240 V
Frequency Range(Hz) 50/ 60
Power consumption < 12 VA
Switching current max(A) 5
Switching voltage max(V) 250
Switching power max(W) 48
Rated operational current AC15.......Ie = 2 A .... Ue = 250 V DC13.......Ie = 2 A .... Ue = 24 V Ie = 0.2 A .... Ue = 125 V Ie = 0.1 A .... Ue = 250 V
Rated impulse voltage(V) 4000
Rated insulation voltage Ui(V) 250
Protection housing IP 30
Protection terminals IP 20
Applied standards UL/CSA

The current relay STW84V monitors up to 8 alternating current sets on current flow yes/no. The inputs can analyse signals of current transformers type STWA1(H) or of potential-free contacts.
For controlling of great dedusting plants several relays can be combined.

Applications
Controlling of dedusting plants in the timber and plastic processing industry according to the technical rules for dangerous materials TRGS 553. The central suction is switched on, as soon as any machine is put into operation. According slide-valves in the suction ducts of the individual machines are opened. In addition, cleaning of a filter (vibration) and a cellular wheel/discharge can be controlled, an external cleaning (with pressurized air) can be started or exceeding of max. volume flow can be reported. The analog output 0...10 V can control a frequency-converter at the motor of the ventilator and thus optimize performance and save energy.

  • Monitoring of 8 machines (STWA1(H) or contact)
  • input for "open all slide-valves"
  • 8 relays (with change-over contacts) for slide-valves
  • 1 relay for control ventilator
  • 1 relay for filter-cleaning
  • 1 relay for control of cellular wheel/discharge or report exceeding max. volume-flow
  • analog output for control of frequency-converter and combination of more STW84V
  • terminals pluggable
  • universal supply voltage AC/DC 24-240 V
  • Accessory: Installation frame ER8 for panel mount

Overview of functions

Functions/adjustments

  • run-after last slide-valve 0... 99 s
  • turn-off delay ventilator 0...99 s
  • minimum volume-flow 1...100 %, (if necessary automatic opening of additional slide-valves, beginning with K8)
  • maximum volume-flow 5... 100 %

Individually adjustable per channel

  • turn-on-delay I1... I8: 0... 20 s
  • turn-off-delay relay K1...K8: 0... 99 s
  • operating value I1...I8: app. 0.5... 5 A
  • volume-flow of slide-valves 1...100 %

Combination of more STW84V
Master-relay considers volume-flow of other relays for

  • control of suction-fan (relay K9 and analog output 0-10 V)
  • opening of additional slide-valves
  • adding time for filter-cleaning
  • report of exceeding max. volume-flow

Control of cleaning (dedusting) of filters

The run time of the suction is added with consideration of the volume flow. The dedusting of the filters is started after the programmed time is reached (starts only with when suction off).

  • time for addition: 0... 99 min.
  • added time stored permanently even at loss of power (power failure or upon completion of work)
  • delay before start of dedusting: 0... 990 s
  • number of dedusting impulses: 0... 20
  • impulse-on-time: 1... 30 s
  • impulse-off-time: 1... 990 s
  • time of continuous dedusting: 0... 990 s
  • alternatively impulse shaking 0.1... 9.9 s (square)
  • alternatively request for external dedusting (with running suction)
  • input for external dedusting command (after next stop of suction)
  • controlling a cellular wheel / discharge during dedusting

Displays and operation

  • 7-segment-display for settings during programming, in operation display of the volume flow
  • 8 LEDs for input/output selection and display of the active inputs/outputs
  • 9 LEDs for function selection
  • easy programming
Write your own review Close Review Form
  • Product can be reviewed only after purchasing it
  • Only registered users can write reviews
  • Bad
  • Excellent
General Catalog

Data Sheet

Video
Request For Quote
Description

The current relay STW84V monitors up to 8 alternating current sets on current flow yes/no. The inputs can analyse signals of current transformers type STWA1(H) or of potential-free contacts.
For controlling of great dedusting plants several relays can be combined.

Applications
Controlling of dedusting plants in the timber and plastic processing industry according to the technical rules for dangerous materials TRGS 553. The central suction is switched on, as soon as any machine is put into operation. According slide-valves in the suction ducts of the individual machines are opened. In addition, cleaning of a filter (vibration) and a cellular wheel/discharge can be controlled, an external cleaning (with pressurized air) can be started or exceeding of max. volume flow can be reported. The analog output 0...10 V can control a frequency-converter at the motor of the ventilator and thus optimize performance and save energy.

  • Monitoring of 8 machines (STWA1(H) or contact)
  • input for "open all slide-valves"
  • 8 relays (with change-over contacts) for slide-valves
  • 1 relay for control ventilator
  • 1 relay for filter-cleaning
  • 1 relay for control of cellular wheel/discharge or report exceeding max. volume-flow
  • analog output for control of frequency-converter and combination of more STW84V
  • terminals pluggable
  • universal supply voltage AC/DC 24-240 V
  • Accessory: Installation frame ER8 for panel mount

Overview of functions

Functions/adjustments

  • run-after last slide-valve 0... 99 s
  • turn-off delay ventilator 0...99 s
  • minimum volume-flow 1...100 %, (if necessary automatic opening of additional slide-valves, beginning with K8)
  • maximum volume-flow 5... 100 %

Individually adjustable per channel

  • turn-on-delay I1... I8: 0... 20 s
  • turn-off-delay relay K1...K8: 0... 99 s
  • operating value I1...I8: app. 0.5... 5 A
  • volume-flow of slide-valves 1...100 %

Combination of more STW84V
Master-relay considers volume-flow of other relays for

  • control of suction-fan (relay K9 and analog output 0-10 V)
  • opening of additional slide-valves
  • adding time for filter-cleaning
  • report of exceeding max. volume-flow

Control of cleaning (dedusting) of filters

The run time of the suction is added with consideration of the volume flow. The dedusting of the filters is started after the programmed time is reached (starts only with when suction off).

  • time for addition: 0... 99 min.
  • added time stored permanently even at loss of power (power failure or upon completion of work)
  • delay before start of dedusting: 0... 990 s
  • number of dedusting impulses: 0... 20
  • impulse-on-time: 1... 30 s
  • impulse-off-time: 1... 990 s
  • time of continuous dedusting: 0... 990 s
  • alternatively impulse shaking 0.1... 9.9 s (square)
  • alternatively request for external dedusting (with running suction)
  • input for external dedusting command (after next stop of suction)
  • controlling a cellular wheel / discharge during dedusting

Displays and operation

  • 7-segment-display for settings during programming, in operation display of the volume flow
  • 8 LEDs for input/output selection and display of the active inputs/outputs
  • 9 LEDs for function selection
  • easy programming
Products specifications
Brand ZIEHL
Country of origin Germany
Rated supply voltage AC/DC 24-240 V
Frequency Range(Hz) 50/ 60
Power consumption < 12 VA
Switching current max(A) 5
Switching voltage max(V) 250
Switching power max(W) 48
Rated operational current AC15.......Ie = 2 A .... Ue = 250 V DC13.......Ie = 2 A .... Ue = 24 V Ie = 0.2 A .... Ue = 125 V Ie = 0.1 A .... Ue = 250 V
Rated impulse voltage(V) 4000
Rated insulation voltage Ui(V) 250
Protection housing IP 30
Protection terminals IP 20
Applied standards UL/CSA
Product tags